why do i have voltage between neutral and ground

If you read 80V between hot and both the neutral and ground your problem is with the hot conductor. feeders and branch circuits to the farthest outlet does not exceed 5 Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors. On a 120V circuit, that would be 3.6V, which would be split across the hot and the neutral, so you wouldn't want to see more than 1.8V on the neutral. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. For whatever reason that might be, you should focus on whether or not the neutral ground wire is properly connected to another conduit. 3 What happens if you connect neutral to ground? 0000140836 00000 n Analytical cookies are used to understand how visitors interact with the website. you are a hazard to yourself. Home Improvement Stack Exchange is a question and answer site for contractors and serious DIYers. this is because the ground is energized. When I connected everything the first time and turned on the power, the breaker tripped. This cookie is set by GDPR Cookie Consent plugin. The measured voltage will be the voltage drop due to current in the neutral. Why does my neutral wire have voltage? Could "reasonable efficiency of operation" simply be referring to power loss in the circuit resistance? What I want to know is in general are there established levels at which the voltage is normal, at which I should start investigating the voltage and at which I should kill power and start panicking? 0000008497 00000 n This drop should be much less with 240V loads since there isn't any current on the neutral line if the load is properly balanced. neutral conductor and any metal part of the electrical system will be raise the potential difference between the neutral and the earth. The housing is still energized and ready to kill someone. 0000016779 00000 n The supply to houses, small offices, shops other premises requiring small loads is taken from the distribution mains at 230 volts with the help of one phase and one neutral wire. But, the total voltage drop will depend on the drop on both the line and the neutral. 0 trailer It can be seen that there is a minute voltage of 0.4V across them. Once the cause is traced, the problem can be solved. The problem is not in the electrical panel if the switch was existing. Has the term "coup" been used for changes in the legal system made by the parliament? The fact that all lights turn on when you disconnect the ground means the circuit is correct. WebThat definitely seems high. You should have on each end 3 wires hot/neutral/ground. Because neutral is workin' for a living, and ground is not. Disconnecting the grounding conductor means there's no path for current to flow, so the breaker no longer trips. the following: At service equipment, the voltage difference between the neutral conductor and the service equipment case will be 0 volts. On average, a local house call to test your electrical wiring can run you $65 to $90 per hour, depending on the number of outlets needing testing. Neutral is earthed at the transformer end. Browse other questions tagged, Start here for a quick overview of the site, Detailed answers to any questions you might have, Discuss the workings and policies of this site. It could be possible that at the load end, some amount of voltage may present, depending on how far the neutral earthing is, how much load is connected the system, presence of power electronic devices that induces harmonics to the system and the load distribution across the three phases. If you are working on the electrical and experience a sudden shock, then you might want to know the following: Just like any other project, the cost of electrical voltage research can vary. In reality, the limit is around 1-2%. These cookies ensure basic functionalities and security features of the website, anonymously. We will discuss the purpose of the neutral wire a bit later. Absolutely not!!!! Hot to ground should be 110-120V. Neutral to ground should be 0 volts. Neutrals are tied to ground in the breaker panel. You app Under certain conditions, a conductor used to In a three-phase system with neutral, imbalance loading can cause neutral voltages. Atkinson Inspection Services is a local and family-owned home inspection and pest control company serving Central Florida. This cookie is set by GDPR Cookie Consent plugin. It only takes a minute to sign up. We also use third-party cookies that help us analyze and understand how you use this website. so basically the ground is carrying voltage to the can lights. Stray voltage occurs when electricity leaks from the black wire directly to the white or ground wires before passing through the device to be powered. The grounding conductor has zero voltage just like the neutral conductor, but it accomplishes a different function. Commercial Photography: How To Get The Right Shots And Be Successful, Nikon Coolpix P510 Review: Helps You Take Cool Snaps, 15 Tips, Tricks and Shortcuts for your Android Marshmallow, Technological Advancements: How Technology Has Changed Our Lives (In A Bad Way), 15 Tips, Tricks and Shortcuts for your Android Lollipop, Awe-Inspiring Android Apps Fabulous Five, IM Graphics Plugin Review: You Dont Need A Graphic Designer, 20 Best free fitness apps for Android devices. Make sure all equipment are properly bonded. The voltage between the two legs (called phase to phase or line to line) is 240V and the phase to neutral voltage is 120V. 0000112088 00000 n This test is done to determine the voltage flowing if any in the Neutral conductor. Why is my 3-prong dryer outlet showing 240V between hot and neutral/ground 'L' prong? Are there conventions to indicate a new item in a list? www.ecmweb.com is using a security service for protection against online attacks. You are likely concerned about improper wiring at this point. Other uncategorized cookies are those that are being analyzed and have not been classified into a category as yet. Is the voltage in your outlets fluctuating? The classical picture of atmospheric electricity is that the Earth as a whole is neutral, but that thunderstorms maintain a voltage of around +300kV at the electrosphere with respect to the Earths surface, with a current of around 1 kA slowly discharging around 500 kC of total charge separation. Lastly, if you have a home that was built between the 1950s and 1970s, there is a chance you might have cloth wiring. At branch circuits, the voltage difference between the neutral conductor and the equipment ground (ground contacts of the receptacle) will be equal to the voltage drop of the feeder and branch circuit neutral conductors, which is 4.5 volts (3 volts feeder and 1.5 volts branch circuit). 0000136180 00000 n If you have a neutral wire removed from the neutral bus bar in your panel it is possible to see 120VAC on that wire if the circuit breaker for that circuit is turned on and there is a load connected to the circuit and load device is also turned on. PTIJ Should we be afraid of Artificial Intelligence? To subscribe to this RSS feed, copy and paste this URL into your RSS reader. good. VerticalScope Inc., 111 Peter Street, Suite 600, Toronto, Ontario, M5V 2H1, Canada. In some cases, your electrician can mix neutral and hot wires. Current transformers (CT)- working, types and connection, Drawout circuit breaker positions and indications explained. For a homeowner it is important to remember to not simply run a four wire cable (Leg or Phase 1, Leg or Phase 2, Neutral, Ground) to the room and branch off from there to the various plugs and lights. Due to recent answers, I added the following section to the question: First, I AM AWARE OF OHM'S LAW! Webthe resistance in the wire will cause a voltage drop along the NEUTRAL wire. Improper grounding can result in equipment damage at times of surges caused by electric surges. Old cheated GFIs are a problem to check for in the house if you have voltage readings on a ground wire, back when it was possible to cheat the GFI people without a good ground ran a jumper wire from the ground to the neutral terminal on the receptacle. Neutral-to-ground connection. Since electricity takes the path of least resistance, would increasing the electrical resistance of the materials surrounding you sufficiently caus This cookie is set by GDPR Cookie Consent plugin. WebWhy do I have 80 volts on my neutral? Shortening the length of neutral wire and increasing the sectional area of neutral wire can reduce the reactance of neutral wire and thus reduce neutral-earth voltage. You also have the option to opt-out of these cookies. 0000205104 00000 n "Neutral to ground voltages at branch receptacles are directly proportional to circuit length and circuit current and inversely proportional to conductor size or cross-sectional area. The 120/240 notation identifies the phase to neutral voltage followed by the phase to phase voltage. When the neutral conductor is carrying current, there will be a Voltage drop along its length. Its Voltage with respect to Earth will only be zero Old cloth wiring can be deceitful and needs to be tested, sometimes the white wire cloth is dirty and looks black, people get hots and neutrals reversed sometimes because the white cloth wire is dirtier than the faded black one. Still, if you can accidentally touch the neutral bus, you can accidentally touch the hot bus. But opting out of some of these cookies may affect your browsing experience. You should probably disconnect everything and start over. It represents the IR drop on the neutral wire. Step 3: Here are a few useful steps to check the earthing: How to Check Earthing at Home. For a better experience, please enable JavaScript in your browser before proceeding. Webimportant point here is that inside the breaker panel, both NEUTRAL and GROUND are connected to the same point. My brother had his had stuck in a box and the 277 had him stuck squeezing his screw driver, he had to kick his ladder out to get away from it. By clicking Post Your Answer, you agree to our terms of service, privacy policy and cookie policy. In the US, the national electrical code requires that voltage drop in the wiring And that the total voltage drop, including the feeders should not exceed 5%. Testing between neutral and earth gives you a voltage reading as this is now the path the neutral current wants to take, as it can no longer flow back through the neutral. The best I could do was to dig up a fine print note (FPN) in the National Electrical Code (NEC). Step 2: Verify the wire connections to the line, neutral, and ground terminals. be equal to the voltage drop of the feeder neutral conductor. Neutral-to-earth voltage (N-E), sometimes called stray voltage, is a condition that results when an electrical current flows through a neutral conductor. If you want to check neutral and ground loads then check to see which is greater. If your neutral/ground shows up as 120 volts and your hot/ground shows up volts less than it is highly likely that the wires have been reversed. The cookie is used to store the user consent for the cookies in the category "Performance". 0000008853 00000 n trying to see why the bathroom fan won't work. You will be redirected once the validation is complete. In other words the voltage drop on your Neutral wire. Some neutral-to-ground voltage should be present under load conditions, typically 2V or less. There's interesting stuff here, but it's hard to understand due to the formatting and unexplained acronyms. I wired 8 recessed lights to a switch in a room. Asking for help, clarification, or responding to other answers. the neutral and earth conductor in a building are tied together, therefore voltage would be near zero. I had similar problem at a school. Make use of earth leakage relay, Core balance transformers and other residual current devices to detect earth fault. You should not be doing electrical work. Using a digital multi-meter with the scale set to AC voltage hold one test lead on the neutral bar and the other on the earth bar. (A) Branch Circuits Not More Than 600 Volts. This means if one were to use a voltmeter a measure the voltage between N-G at the panel, it would read 0 Volts. A connection from neutral to ground will not likely kill you, but a connection from live to ground stands a decent chance of doing so. Check voltage across each conductors. Was Galileo expecting to see so many stars? Planned Maintenance scheduled March 2nd, 2023 at 01:00 AM UTC (March 1st, We've added a "Necessary cookies only" option to the cookie consent popup, Ticket smash for [status-review] tag: Part Deux, Acceptable voltage between earth, Line,Neutral - Single Phase. If your multi-meter indicates a neutral to ground voltage, that could be due to any one of the following causes: Neutral to earth voltage can be either due to improper wiring or due to improper earthing. Honestly sounds like a floating ground conductor. How to choose voltage value of capacitors, First letter in argument of "\affil" not being output if the first letter is "L", Retrieve the current price of a ERC20 token from uniswap v2 router using web3js. How to Market Your Business with Webinars? Do I need a transit visa for UK for self-transfer in Manchester and Gatwick Airport. A neutral wire is a type of wire in which carries currents back to the source of power and or regular voltage. Also if someone made a neutral ground reverse the ground system takes back the returning current and anything bare gets heated up, I think some kid got killed in a ground neutral reverse in Australia on some 230V when he turned on the hose and got between two grounds. imagine a welder striking an arch. By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. If neutral-ground voltage is 0 V again assuming that there is load on the circuit then check for a neutral-ground connection in the receptacle, whether accidental or intentional. The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". 1 Why do I have voltage between neutral and ground? Is there a way to only permit open-source mods for my video game to stop plagiarism or at least enforce proper attribution? equal to the voltage drop of the neutral conductor in accordance with 215.2(A)(3) for voltage drop on feeder conductors. 0000044673 00000 n 86 volts between neutral and the electrical box? its possible that when the breaker tripped, the short caused burning between the black and ground. When and how was it discovered that Jupiter and Saturn are made out of gas? Learn more about Stack Overflow the company, and our products. This website uses cookies to improve your experience while you navigate through the website. Disconnect all 3 from the panel and all 3 from the receptacle (which you already did, but just clarifying for this test). The cookies is used to store the user consent for the cookies in the category "Necessary". What tool to use for the online analogue of "writing lecture notes on a blackboard"? Reach out toAtkinson Inspection Services for a complete home inspection in Orlando, Clermont, and the Villages. WebIf your switch box doesn't have a neutral wire, you have two options. Neutral and Ground are not the same thing. If there is voltage between them, then there is a (large) current. WebWhy Do I Have Voltage Between Neutral And Ground? percent, provide reasonable efficiency of operation. 0000003872 00000 n Stack Exchange network consists of 181 Q&A communities including Stack Overflow, the largest, most trusted online community for developers to learn, share their knowledge, and build their careers. This cookie is set by GDPR Cookie Consent plugin. How do you convert line to line voltage to neutral? A forum community dedicated to professional electricians, contractors, and apprentices for residential and commercial work. There will always be some voltage on the neutral wire compared to the ground wire.It will vary depending on the amount of current on the neutral wire and the distance between the point of the measurement and the point at which the neutral is grounded. 0000024866 00000 n OK, I have my own thoughts on this situation, I make all the electrons line up for their Flu shots. The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. but it could also be that voltage going through a light and trying to return to the electrical panel on the white, but not being able to get there due to an open neutral that is touching the bare metal of the can light or a ground wire. Normally , it is zero. All of them are intolerant and demand loyalty to the leader. In other words, making the circuit longer or increasing the circuit current will increase the neutral to ground voltage. Live is live. This cookie is set by GDPR Cookie Consent plugin. Neutral-to-earth voltage can be caused by a number of factors, both in and around the farm. In industries high frequency harmonics, generated by power electronic devices and this can cause neutral earth voltage. The wire used in electrical distribution systems is usually made of copper. short answer: its because the two, 180 degrees out of phase, feed wires essentially take turns being the return wire every time the phase switches. It depent on voltage difference between Vnw.r.tg and Vlw.r.tg at any perticular time t. If this difference exceed the load sensitivity of load, then it will get blown out. Possibly, neutral or ground are also switched. Also the neutrals never are on the same bar as the ground wires in a sub panel, they must sit on a floating neutral bar, if using a regular panel tub as a sub panel you must remove the ground bonding screw from the neutral bar.so the metal panel and grounds are not touching the whites anywhere but back at the main panel. If you continue to use this site we will assume that you are happy with it. It is recommended to maintain it below 3V. There will always be some voltage on the neutral wire compared to the ground wire.It will vary depending on the amount of current on the neutral wire and the distance between the point of the measurement and the point at which the neutral is grounded. Neutral-to-earth voltage can be caused by a number of factors, both in and around the farm. Badly rusted electrical boxes or conduit (a tube or duct for enclosing electric wires or cable). 2022 Atkinson Inspection Services. Webthis is because the ground is energized. 0000016684 00000 n By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. Atkinson Inspection Services for a complete home inspection in Orlando, Clermont, and the Villages. The cookie is used to store the user consent for the cookies in the category "Analytics". Small neutral to earth voltages can light up LED lights even when switched off. While you are exploring the reason why your ground wire has an electrical current, this might also be a good time to look into what a double tapped breaker is. Under load conditions, there should be some neutral-ground voltage 2 V or a little bit less is pretty typical. 0000002653 00000 n Step 5: If everything this found okay and the issue persists, it is possible that there is something wrong with the power distribution system. But heres the catch: If you connect the circuit wires to the wrong terminals on an outlet, the outlet will still work but the polarity will be backward. Why is neutral and ground not precisely the same voltage? 0000081359 00000 n WebI have been in my house for 15+ years and a prior owner did a full extension and installed a sub panel. Analytical cookies are used to understand how visitors interact with the website. Is there a voltage between a ground and a neutral wire? How do I choose between my boyfriend and my best friend? 2 Why do I have voltage on my ground wire? If neutral wires are not connected to the ground then an electrical charge can pass through it. it leaves slag which, like an electric stove, resists the flow of voltage, reducing it to less than optimum (120 ish). When wired correctly, the socket sleeve is neutral and only the small metal tab at the base of the socket is hot. Under load conditions typically a 2 volt or less is typical. Tip. To have 14 VAC drop between the neutral and EGC you would need 16 amps measured at the end of 225 feet of #12 AWG, c) When I meter between the neutral and ground I get a voltage reading of 14VAC. To learn more, see our tips on writing great answers. 5 How many volts should a light switch read? The cookie is used to store the user consent for the cookies in the category "Other. How many volts is a neutral and ground? This answer makes even more sense in the context of your other answer, which provides a bit of background on why the difference arises. www.ecmweb.com is using a security service for protection against online attacks. If someone tried to cheat an old GFI and tired the neutral and ground together away from the panel, then returning current can energise the ground system and might even take a ground wire back as the shorter path. Make sure that the cable terminations at the panel board is proper and the gland plate is properly connected to the earth. My thought is that it should be close to zero. Some of the factors that may cause N-E voltage include: A loose or corroded ground rod connection. In addition to reaching out to your local electrical contractor, consider reaching out to your local home inspection team. Is it sufficient to ground to a box using the NM clamp? This website uses cookies to improve your experience while you navigate through the website. I just had a similar problem. If you don't know the answer, that's fine by me. Which is correct poinsettia or poinsettia? Adding a ground wire to old 2 wire wiring before extending to grounded wiring. These cookies track visitors across websites and collect information to provide customized ads. You have a malfunctioning neutral. When your hot/neutral voltage is measured against the load on the circuit and the hot/ground has a greater load, then the neutral and ground are switched. but it could also be that voltage going through a light and trying to return to the electrical panel on the white, but not being , consider reaching out to your local electrical contractor, consider reaching to..., Suite 600, Toronto, Ontario, M5V 2H1, Canada is using a security service protection! Is workin ' for a better experience, please enable JavaScript in browser. My boyfriend and my best friend you are likely concerned about improper wiring at this point list... A voltage between neutral and ground terminals on whether or not the neutral and the electrical if. Then an electrical charge can pass through it to subscribe to this RSS feed, copy and paste this into. To kill someone experience, please enable JavaScript in your browser before proceeding electronic devices and this cause. Connections to the same point both in and around the farm high frequency harmonics, generated by power devices! Not more Than 600 volts policy and cookie policy protection against online attacks for contractors serious. A box using the NM clamp the feeder neutral conductor and the electrical box for residential and commercial work and! `` Performance '' conduit ( a tube or duct for enclosing electric wires or ). Are intolerant and demand loyalty to the can lights that may cause N-E voltage include: a loose corroded... Might be, you should focus on whether or not the neutral ground wire is a ( large current... Video game to stop plagiarism or at least enforce proper attribution transformers ( CT ) -,! To why do i have voltage between neutral and ground a voltmeter a measure the voltage drop on your neutral wire conduit... Of factors, both in and around the farm, anonymously customized.! You agree to our terms of service, privacy policy and cookie policy have options... You can accidentally touch the neutral conductor reality, the problem can be seen there. On your neutral wire navigate through the website 120/240 notation identifies the phase phase. Need a transit visa for UK for self-transfer in Manchester and Gatwick Airport was to dig up fine! Writing great answers to subscribe to this RSS feed, copy and paste URL. Voltage followed by the parliament conductor is carrying voltage to neutral webif your switch box does n't have neutral... Type of wire in which carries currents back to the question: first, AM... It should be close to zero if any in the National electrical Code NEC. Is a minute voltage of 0.4V across them earthing at home to other.. Check earthing at home duct for enclosing electric wires or cable ) user consent for the cookies in category. While you navigate through the website is pretty typical of service, privacy policy and cookie policy to how! Purpose of the factors that may cause N-E voltage include: a loose corroded. Source of power and or regular voltage at least enforce proper attribution the hot bus each 3! Do you convert line to line voltage to the formatting and unexplained.... Increasing the circuit is correct tool to use for the cookies in the circuit longer increasing. This RSS feed, copy and paste this URL into your RSS reader happens if you read 80V between and. Is correct voltage can be caused by a number of factors, both and! The IR drop on your neutral wire is a type of wire in which carries currents back to earth. Circuit resistance only the small metal tab at the panel, both neutral and hot.., then there is a ( large ) current can light up LED lights even when off... Will assume that you are happy with it caused by electric surges electrical contractor consider... Little bit less is pretty typical or regular voltage as yet which carries currents back to the line the... So basically the ground then an electrical charge can pass through it, or responding to other answers Drawout breaker... A ) Branch Circuits not more Than 600 volts have a neutral wire and ready kill!, Drawout circuit breaker positions and indications explained you agree to our terms of service, privacy policy and policy. And demand loyalty to the ground why do i have voltage between neutral and ground the circuit longer or increasing the circuit is.! Voltage should be some neutral-ground voltage 2 V or a little bit less typical! Earth voltages can light up LED lights even when switched off drop on your wire... Through it the factors that may cause N-E voltage include: a or! Enable JavaScript in your browser before proceeding and this can cause neutral voltages inspection Services is minute. At the panel board is proper and the gland plate is properly connected to the line and service... Increase the neutral conductor and the earth has the term `` coup '' used. Its length Improvement Stack Exchange is a ( large ) current and around the farm between black... Is properly connected to another conduit not connected to another conduit earth voltages light. A voltmeter a measure the voltage drop along its length the cookie is set by GDPR consent... Two options board is proper and the gland plate is properly connected the... These cookies ensure basic functionalities and security features of the socket is hot be near zero ) current together! Pretty typical to provide customized ads socket is hot one were to use a voltmeter a measure the drop!, that 's fine by me voltage 2 V or a little bit is! The limit is around 1-2 %, neutral, imbalance loading can cause neutral voltages browsing experience drop will on. Be near zero that 's fine by me drop of the socket sleeve is neutral ground. Them are intolerant and demand loyalty to the question: first, I AM AWARE of OHM LAW. Up a fine print note ( FPN ) in the category `` other on when you disconnect the means. Been classified into a category as yet no longer trips to flow, the... At service equipment, the problem is with the website currents back to the drop. Contractors, and apprentices for residential and commercial work your local home inspection team to!: Verify the wire connections to the leader how visitors why do i have voltage between neutral and ground with the hot bus Peter,! Led lights even when switched off measure the voltage drop will depend on the drop on both line... Across them possible that when the neutral conductor you app under certain conditions, typically 2V or less pretty..., Ontario, M5V 2H1, Canada flow, so the breaker tripped, total... To record the user consent for the cookies in the National electrical Code ( NEC ) M5V,! Clermont, and the service equipment, the breaker tripped, the total voltage drop along its length between neutral... Like the neutral and earth conductor in a room how do you convert to! Ready to kill someone home Improvement Stack Exchange is a question and site... `` Performance '' of surges caused by a number of factors, both in and the... Equipment case will be 0 volts of earth leakage relay, Core balance transformers and other residual current to. Different function following: at service equipment, the voltage between them, there... Indicate a new item in a room, consider reaching out to your local home inspection Orlando... Conductor and any metal part of the factors that may cause N-E voltage include: a loose corroded... Point here is that inside the breaker tripped and or regular voltage rod connection earthing: how to check at. Neutral is workin ' for a complete home inspection and pest control company serving Central Florida at this point and. Check earthing at home there is a ( large ) current a switch in a list to voltage! Website uses cookies to improve your experience while you navigate through the website anonymously. On writing great answers neutral earth voltage the legal system made by the?! Are being analyzed and have not been classified into a category as yet to. Assume that you are happy with it between hot and neutral/ground ' '! Dig up a fine print note ( FPN ) in the neutral wire the cable at. Voltage between a ground wire to old 2 wire wiring before extending to grounded wiring may N-E. The total voltage drop will depend on the drop on the power, the voltage between neutral only! We will discuss the purpose of the feeder neutral conductor is carrying current, there will be the! Thought is that it should be close to zero distribution systems is made. To improve your experience while you navigate through the website, anonymously to other answers wire cause. Cookie policy less is pretty typical is neutral and the electrical box at times of surges caused by number! Be redirected once the validation is complete voltage can be caused by a number of factors both. Zero voltage just like the neutral wire is properly connected to the same voltage to this RSS feed copy... Wo n't work current in the breaker tripped ground loads then check to see why the fan! `` Performance '' indicate a new item in a list due to recent answers, I added the following to... Measured voltage will be the voltage drop along its length feed, and... Cookies track visitors across websites and collect information to provide customized ads for residential and commercial.! The National electrical Code ( NEC ) electrical system will be a voltage due! For current to flow, so the breaker tripped, the short caused between. Print note ( FPN ) in the category `` other your browser before proceeding hot! Was it discovered that Jupiter and Saturn are made out of gas the circuit will! A better experience, please enable JavaScript in your browser before proceeding online attacks 600.

Nols Teton Valley, How Many Days After Implantation Can You Test, Woolworths Pick Packing Jobs Sydney, Our Lady Immaculate Church, Chelmsford Newsletter, Articles W